This mechanical splice is a high performance, low cost, easy to install, fully mechanical Fibre Optic Splice. Employing a visible glass capillary alignment member, that is preloaded with index matching gel, the user can inspect the fibre location during installation. The splice is tunable and reusable for most emergency or permanent installation requirements.
Overview of the installation procedure
Prepare, clean and cleave the fibre ends. The Cleave Length should be 7-9 millimetres as illustrated below
Align and butt the cleaved end faces of the optical fibres in the visible central glass guide. The moulded-in springs hold the buffers during installation and/or tuning, without the need for any extra tooling or fixturing.
To permanently secure the fibre(s), twist the grey locking nut (like a wire nut) to lock the internal Collette onto the buffer. This action is similar to a Pin Vice or Drill Chuck, as it firmly grips the buffer when the nut is tightened. It provides a higher retention that the fibre or buffer tensile strength. Specifications of Mechanical Splice
-
Mechanical splice has a glass reinforced Liquid Crystal Polymer (LCP) plastic housing.
-
Outside Dimensions: Length: 40mm Diameter: (max) 5.7mm
-
Average Splicing Loss: Less than 0.2dB and is tunable for minimum loss
-
Mean Loss: Less than 0.007dB and is tunable for minimum loss
-
Back Reflection (return loss): -50dB
-
Loss Variation During Thermal Cycling (-40 to +80 șC): Less than 0.1dB
-
Fibre Retention: Greater than 1,250 grams
-
Coating Acceptance (buffer size): One splice accepts any combination from 250-900 microns
-
Installation Time: 30 to 45 seconds (after fibre preparation)
Features
|