Noyes Networks Test & Measurement Equipment
|
|
ORL3 - Optic Return Loss Test Set |
|
ORL3 - Optic Return Loss Test Set
Features:
-
1310 / 1550 nm Return Loss
-
Measures up to +23 dBm in OPM Mode
-
Store up to 900 Loss Readings
-
Field Portable, Battery Operated
-
Lightweight
-
Non-Volatile Memory
-
Selectable Threshold
-
AC Charger
|

|
|
The ORL 3 has been designed to test reflections from connectors and components in high speed digital and analog systems such as Telco, CATV, and WAN's. The ORL 3 provides the ability to perform both return loss (ORL mode), and loss measurements (OLTS mode) at 1310 nm and 1550 nm. The selectable threshold function is available for each wavelength when measuring in the ORL mode. When measurements exceed the set threshold level then PASS will appear in the liquid crystal display.
As an optical power meter (OPM mode) the ORL 3-4 measures up to +23 dBm for high output systems such as CATV and amplifiers. The supplied Test! software allows the ORL 3 to be connected to a PC for real time measurements and long term stability tests when operating in OPM mode.
The non-volatile memory stores up to 900 loss readings for down loading to a PC or printer for full fibre documentation. The test set is also equipped to generate and detect a 2 kHz tone for isolating specific fibres from a bundle when used with an optical fibre identifier such as the Noyes Fiber Systems OFI 200.
The power options of the ORL 3 provide flexibility by offering the ability to operate from three different power sources. The test set will operate from the rechargeable NiCad batteries, 9 volt alkaline batteries, or an AC power adapter.
The ORL 3 is delivered complete with PC Test! software, serial transfer cable, instruction manual, adapter cap, fibre optic reference cable, mandrel, screwdriver, hex key screwdriver, protective rubber boot, AC adapter/charger, and soft carrying case. |
|
Specifications
|
Model |
ORL 3-3 |
ORL 3-4 |
|
Power Meter Specifications |
|
Detector Type |
InGaAs |
Filtered InGaAs |
|
Measurement Range |
+6 to -70dBm |
+23 to -45dBm |
|
Calibrated Wavelengths1 |
1310,1550nm |
|
Accuracy2 |
±0.25dB |
|
Resolution |
0.01dB |
|
Units Displayed |
dB, dBm, Watts |
|
Connector Type |
Universal Adaptor Interface |
|
Return Loss Specifications3 |
|
Dynamic Range |
65dB |
|
Accuracy |
±0.5dB4 |
|
Spectral Width (FWHM) |
≤6nm Laser |
|
Centre Wavelength |
1310/1550 ±20nm |
|
Connector Type (specify when ordering) |
FC/APC5 |
|
Insertion Loss Specifications |
|
Dynamic Range |
60dB |
|
Output Stability |
±0.1dB/8hrs |
|
Output Power |
-10dB minimum |
|
Accuracy |
±0.1dB3 |
|
Centre Wavelengths |
1310, 1550nm |
|
General Specifications |
|
Operating Temperature |
0° to 40°C 90% non-condensing |
|
Storage Temperature |
-20° to 60°C |
|
Size |
8.25" H x 4" W x 1.75" D (21x10x4.5 cm) |
|
Weight |
1lb 9oz (700grams) |
|
Power |
Alkaline, NiCad rechargeable, AC |
|
Battery Life |
8hrs with NiCad |
|
1Single wavelength models available |
|
2Specified at-10dBm at 26°C, N.I.S.T.
traceable |
|
3Specifications are 25 ±2°C |
|
4From 25 to 55dB |
|
5A variety of hybrid connections are
available |
|
|
|