Noyes Networks Test & Measurement Equipment
|
|
OPM 5 - Optical Power Meter |
|
OPM 5 - Optical Power Meter
Features:
-
850, 980, 1300, 1310, 1480, 1550, and 1625
nm
-
Singlemode and Multimode
-
Store 500 Loss Readings per Wavelength
-
Field Portable, Battery Operated
-
Downloads to Printer
-
N.I.S.T. Traceable
|

|
|
|
The OPM 5 offers more features than any
comparably priced optical power meter available today. By bringing all the
features of expensive laboratory meters into a rugged, hand held package,
the OPM 5 raises field testing to a new standard.
The OPM 5 performs diagnostic and evaluation
measurements associated with fibre optic transmission systems and cable
plant in dB, dBm, and micro-watts. The non-volatile memory of the OPM 5
stores 250 loss readings per wavelength for future downloading to a printer
or computer. The OPM 5 offers the ability to re-measure any specific memory
location without erasing or modifying loss readings already in memory.
The supplied test software provides a new
level of optical power meter testing. The software can be used to retrieve
the stored data from the memory of the OPM 5 and then print reports for full
fibre documentation. The software also allows the OPM 5 to be connected to
the PC for real time measurements and long term stability tests,
transforming the OPM 5 into the equivalent of a powerful laboratory bench
model.
The OPM 5 will operate from 9 volt alkaline
batteries or an AC power adapter. If extended battery life is a concern,
then the automatic shut down feature can be activated and will occur if no
keys are pressed within a five minute period.
The OPM 5 is delivered complete with PC
test software, serial transfer cable, manual, hard carrying case, 9 volt
battery, 2 recording pads, and protective rubber boot. Optical light sources
and optical power meters from Noyes Fiber Systems can be packaged together
as a kit.
Please call for more test kit information (0870 121 9990)
|
|
Specifications
|
MODELS |
OPM 5-2C |
OPM 5-3C |
OPM 5-4C |
|
Tone Detection Specifications |
|
Calibration Wavelength (nm) |
850 |
1300, 1310, 1550 |
850 |
1300, 1310, 1550 |
850, 980 |
1300, 1310, 1480, 1550, 1625 |
|
Tone Detection Range (dBm) |
+6 to -30 |
+6 to -35 |
+6 to -30 |
+6 to -40 |
+26 to -10 |
+26 to -20 |
|
Tone Detection Frequency (Hz) |
270 ± 13.5 |
|
1000 ± 50 |
|
2000 ± 300 |
|
Optical Specifications |
|
Detector Type |
Germanium (Ge) |
InGaAs |
Filtered InGaAs |
|
Display Range (dBm) |
+6 to -60 |
+6 to -70 |
+26 to -50 |
|
Accuracy (@ 25°C & -10.0dBm) |
±0.25 dB |
|
Resolution |
0.01 dB (.1 dB selectable) |
|
General Specifications |
|
Battery Life |
>30 hrs. typical operation with 9V Alkaline |
|
Adapter Caps |
Order Separately (ST, SC, FC and others available) |
|
Size (H x W x H) |
5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm) |
|
Weight |
0.56 lb (0.26 kg) |
|
Operating Temp. |
0° to 50° C |
|
Storage Temp. |
-30° to 60° C |
|
Relative Humidity |
0 to 95% (non-condensing) |
|
|
|