To contact AURIGA phone 0870 121 9990 fax 0870 121 9991 or email | if you have any problems or feedback please direct them to the webmaster

   home | about | contact | e-catalogue | products | special offers | news | archive | press | site map   

 

Noyes Products

Noyes Overview

 

Noyes Networks Test & Measurement Equipment

 

MLP 5-2b - Fibre Optic Loss Test Kit

 

MLP 5-2b - Fibre Optic Loss Test Kit  

Features:

  • Loss Measurements at 850 nm and 1300 nm

  • Multimode and Singlemode Testing

  • Set Reference for Each Wavelength

  • Small Size, Field Portable

  • Battery Operated

  • Connects to PC for Additional Testing Options

  • N.I.S.T. Traceable

The Noyes MLP 5-2B test kit raises field testing to new standards by combining our popular OPM 5-2C optical power meter, and the OLS 1-2 optical light source in a rugged carrying case. Used during installations, the MLP 5-2B performs end to end loss measurements on multimode fibre at 850, and 1300 nm, as well as measurements on singlemode fibre at 1300 nm.

The OPM 5-2C stores 250 loss readings for each wavelength in non-volatile memory for future downloading to a computer, or printer. In addition, the OPM 5-2C will remeasure any specific memory location without erasing, or modifying other loss readings.

When the OPM 5-2C is linked directly to a computer during testing, the unit is transformed into a powerful diagnostic lab meter. The included software offers real-time measurements for extensive stability testing.

The MLP 5-2B test kit comes equipped with a OPM 5-2C and an OLS 1-Dual along with one ST or SC adapter cap, soft carry case, software, serial cable, trace pad, protective rubber boots, and operations manual. Additional items may be needed, such as patch cords, couplings, and adapter caps (depending upon the type of testing).

Specifications

 

MODEL  MLP 5-2B
Optical Power Meter  OPM 5-2C
Calibration Wavelength (nm)  850 1300, 1310, 1550
Tone Detection Range (dBm)  +6 to -30 +6 to -35
Tone Detection Frequency (Hz)  270 ±13.5, 1000 ±50, 2000 ±300
Detector Type  Germanium (Ge)
Measurement Range  +6 to -60dBm
Accuracy (@25° C & -10.0 dBm)  ±0.25dB
Resolution  0.01dB (.1dB selectable)
Power  >30hrs. typical operation with 9V alkaline
Adapter Caps  order separately (ST, SC, FC, and others available)
Size (H x W x D)  5.5 x 3.2 x 1.5in (14.0 x 8.1 x 3.8cm)
Optical Light Source  OLS 1-Dual
Emitter Type  LED
Emitter Classification  Class 1, IEC 825
Spectral Width  40, 100nm
Wavelength  850, 1300nm
Stability (@25° C & 5 min. warm-up)  ±1dB/8 hrs.
Output Power  
Multimode (62.5/125 µm)  -20dBm @ 850nm, -20dBm @ 1300nm
Singlemode (9/125 µm)  -40dBm @ 1300nm
Power  40hrs. typical operation with 9V alkaline, AC adapter optional
Optical Adaptors  ST or SC
Size (H x W x D)  4.6 x 2.6 x 1.2in (11.6 x 6.6 x 3.1cm)
General Kit Specifications
Dynamic Range of Test Kit  
Multimode (62.5/125 µm)  40dB @ 850 & 1300nm
Singlemode (9/125 µm)  18dB @ 1300nm
Weight  2lb 9oz (1.29kg)
Size (H x W x D)  9.0 x 12.25 x 4.0in (22.8 x 31.1 x 10.1cm)
Operating Temperature  0° to 50°C
Storage Temperature  -30° to 60°C
Specifications are subject to change.    
© AURIGA (europe) PLC 2004, E&OE | last updated 27-10-05 09:10 | Privacy Statement | Site Map | Help