To contact AURIGA phone 0870 121 9990 fax 0870 121 9991 or email | if you have any problems or feedback please direct them to the webmaster

   home | about | contact | e-catalogue | products | special offers | news | archive | press | site map   

 

Noyes Products

Noyes Overview

 

Noyes Networks Test & Measurement Equipment

 

MLP 1 - Fibre Optic Loss Test Kit

 

MLP 1 - Fibre Optic Loss Test Kit 

Features:

  • Multimode and Single-mode Testing

  • Loss Measurements at 850nm and 1300nm

  • Certify 50 or 62.5µm multimode fibre links for any 850 or 1300nm application, including Gigabit Ethernet (GBE)

  • Includes 50 and 62.5 µm mandrels

  • Field portable, battery operated

  • N.I.S.T. Traceable

The MLP1 Test Kits are inexpensive solutions for testing multimode and singlemode systems.

Two versions of the MLP1 Test Kit are available for testing Premises networks, LAN, and Gigabit Ethernet.

The MLP1-1S Test Kit includes the OPM1-2C Optical Power Meter and OLS1-1 Optical Light Source, which operates at 850nm.

The MLP1-2 Test Kit combines the OPM 1-2C Optical Power Meter and OLS1-2 Optical Light Source, which operates at 850 and 1300nm.

The OPM1-2C Optical Power Meter measures power at 850, 1300, 1310, and 1550nm.

The OLS1 Optical Light Source operates at 850 and 1300nm for use on Ethernet, Gigabit Ethernet, Token Ring, and FDDI. The 1300nm output can also be used to test short distance (up to 20km) single-mode fiber links.

The MLP1 Test Kit includes an OLS1 Optical Light Source, OPM1 Optical Power Meter, protective rubber boots, adapter cap, 50 and 62.5 µm mandrels, MLP1 user's guide, warranty registration card, and carry case.

Specifications

 

MODEL  MLP1-1S  MLP1-2
Optical Light Source  OLS1-1  OLS1-2
Wavelength  850nm  850, 1300nm
Spectral Width  40nm  40, 120nm
Emitter Type  LED
Stability (@25°C & 5 min. warm-up)  0.1 dB/8hrs.
Output Power
Multimode( 62.5/125 µm)  20dBm @ 850nm, -20dBm @ 1300nm
Singlemode ( 9/125 µm)  -40dBm @ 1300nm
Power  80hrs. typical with 9V alkaline, AC adapter optional
Connector  ST
Size (H x W x D)  4.6 x 2.6 x 1.2in (11.6 x 6.6 x 3.1cm)
Optical Power Meter  OPM1-2C
Calibration Wavelength  850, 1300, 1310, 1550nm
Detector Type  Germanium
Dynamic Range  +6 to -60dBm
Accuracy (@ 25°C & -10.0 dBm)  ±0.25dB
Resolution  0.1dB
Power  >60hrs. typical operation with 9V alkaline
Adapter Caps  order separately (ST, SC, FC, and others available)
Size (H x W x D)  5.5 x 3.2 x 1.5in (14.0 x 8.1 x 3.8cm)
General Kit Specifications  MLP1-1S  MLP1-2
Dynamic Range of Test Kit
Multimode ( 62.5/125 µm)  40dB @ 850nm  40dB @ 850 & 1300nm
Singlemode ( 9/125 µm)    20dB @ 1300nm
Weight  2lbs. 9oz. (1.29kg)
Dimensions (H x W x D)  9.0 x 12.25 x 4.0in (22.8 x 31.1 x 10.1cm)
Operating Temperature  0 to 50°C
Storage Temperature  -30 to 60°C

Specifications are subject to change.